ISOLPACK has strategically bet on the excellent quality of its products: specialized technicians, engineers and chemists dedicate themselves to research and development, for a continuous improvement of products and services; the feedback received from the Italian and foreign market confirms the success of ISOLPACK quality.
 

 

 

Select the table you want to view ...

 

FIRE REACTION CLASSIFICATION
 

ISOLPACK products have numerous fire resistance certificates issued by authorized laboratories, according to nationally and internationally recognized standards. The careful selection of raw materials, the advanced production processes, the numerous quality controls, in accordance with the CE marking legislation, are a guarantee of reliability and safety.

 

FIRE REACTION THICKNESSES
CLASS MATERIAL CATEGORY PRODUCT 30 35 40 50 60 70 80 100 120 140 150 160 180 200 220 240
A2-s1,d0 MINERAL WOOL ROOF LITHOS       x x   x x x   x     x    
A2-s1,d0 MINERAL WOOL WALL FIBERMET       x x   x x x   x     x    
A2-s1,d0 MINERAL WOOL WALL FIBERSTAR             x x x   x     x    
A2-s1,d0 WOOL GLASS ROOF LITHOS G       x x   x x x   x     x    
A2-s1,d0 WOOL GLASS WALL FIBERMET G       x x   x x x   x     x    
A2-s1,d0 WOOL GLASS WALL FIBERSTAR G       x x   x x x   x     x    
B-s1,d0 PIR POLYURETHANE ROOF DELTA 5               x                
B-s1,d0 PIR POLYURETHANE WALL ALFA 2               x                
B-s1,d0 PIR POLYURETHANE WALL STAR               x                
B-s1,d0 PIR POLYURETHANE WALL WFJ               x                
B-s2,d0 PIR POLYURETHANE ROOF DELTA 3 x x x x x   x x x x            
B-s2,d0 PIR POLYURETHANE ROOF DELTA 5 x x x x x   x x x x            
B-s2,d0 PIR POLYURETHANE ROOF EV1M x x x x x   x x x x            
B-s2,d0 PIR POLYURETHANE ROOF SUPERCOPPO     x   x   x x                
B-s2,d0 PIR POLYURETHANE WALL ALFA 1 x x x x x   x x x x x x x x    
B-s2,d0 PIR POLYURETHANE WALL ALFA 2 x x x x x   x x x x x x x x    
B-s2,d0 PIR POLYURETHANE WALL STAR     x x x   x x x x            
B-s2,d0 PIR POLYURETHANE WALL ONDA           x x x                
B-s2,d0 PIR POLYURETHANE WALL WFJ               x x x x x x x x x
B-s2,d0 PIR POLYURETHANE WALL WSJ x   x x x   x x x x x x        


The fire reaction classification was obtained according to the regulation EN 13501:2007+A1:2009.

 

 

 

FIRE RESISTANCE CLASSIFICATION
 

The panels have a fire resistance ranging from EI 20 to EI 180 and from REI 30 to REI 120, that means they can resist fire for 180 precious minutes, preserving the seal and thermal insulation. Furthermore, the fibrous structure of the rock wool favors the absorption of acoustic waves and allows to attenuate the intensity and propagation of noise. Today it is the only material that manages to combine four fundamental qualities: fire protection, incombustibility, thermal insulation and sound absorption.

 

FIRE RESISTANCE THICKNESSES
CLASS MATERIAL CATEGORY PRODUCT 50 60 80 100 150
REI120 MINERAL WOOL ROOF LITHOS       x  
REI120 MINERAL WOOL ROOF LITHOS MICRO-PERFORATED         x
REI60 MINERAL WOOL ROOF LITHOS     x    
REI30 MINERAL WOOL ROOF LITHOS x        
REI30 PIR POLYURETHANE ROOF DELTA 5       x  
EI180 MINERAL WOOL WALL FIBERMET       x  
EI120 MINERAL WOOL WALL FIBERMET       x  
EI90 MINERAL WOOL WALL FIBERSTAR       x  
EI90 MINERAL WOOL WALL FIBERSTAR     x    
EI60 MINERAL WOOL WALL FIBERMET     x    
EI60 MINERAL WOOL WALL FIBERSTAR     x x  
EI45 WOOL GLASS WALL FIBERMET G       x  
EI30 MINERAL WOOL WALL FIBERMET x x x x  
EI30 PIR POLYURETHANE WALL ALFA 2       x  
EI20 PIR POLYURETHANE WALL ALFA 2     x x  


The fire resistance classification was obtained according to the regulation EN 13501:2007+A1:2009.

 

 

 

EXTERNAL FIRE RESISTANCE CLASSIFICATION
 

The BROOF certification represents the specific assessment of the risk of propagation of the roof coverings and the reaction to fire class to external fires. The identification of the test method used is generally indicated by (t1), (t2), (t3), where the numerical progression does not indicate a greater or lesser fire resistance but a different test method. (t3), for instance, trigger with hot embers, wind and heat input.

 

EXTERNAL FIRE RESISTANCE THICKNESSES
CLASS MATERIAL CATEGORY PRODUCT 30 40 50 60 80 100 120
Broof (t3) PUR POLYURETHANE ROOF DELTA 5 x x x x x x x
Broof (t3) PUR POLYURETHANE ROOF KAPPA 5 x x x x x x x


The external fire resistance classification was obtained according to the regulations EN 13501-5:2016 - CEN TS 1187-3.

 

 

 

SOUNDPROOFING CLASSIFICATION
 

We absorb it, isolate it and neutralize it. We treat noise this way, both coming from outside and inside. Through soundproofing panels in the first case and sound absorbing in the second. Because high noise, but also the so-called "background" noise, can be harmful to health, causing stress and inefficient production. For this reason it is advisable to intervene with solutions designed to improve our comfort, both at home and at workplace. With the Sound line panels that guarantee excellent sound insulation and high sound absorption.

 

SOUNDPROOFING THICKNESSES
CLASS MATERIAL CATEGORY PRODUCT 50 100
Rw=34,7 dB MINERAL WOOL WALL FIBERMET MICRO-PERFORATED   x
Rw=33,6 dB MINERAL WOOL WALL FIBERMET MICRO-PERFORATED x  


The acoustic insulation classification was obtained according to the regulation EN 10140-2:2010 - EN 717-1:2013.

 

 

 

SOUND ABSORPTION CLASSIFICATION
 

The knowledge of the acoustic level of absorption of a material allows to predict how "reverberating" an enviroment would be and how much intense would be the noise produced by a particular sound source. αW = sound absorption coefficient.

 

SOUND ABSORPTION THICKNESSES
CLASS MATERIAL CATEGORY PRODUCT 50 80 100 150
α=0,95 MINERAL WOOL ROOF LITHOS MICRO-PERFORATED       x
α=0,90 MINERAL WOOL WALL FIBERMET MICRO-PERFORATED     x  
α=0,80 MINERAL WOOL WALL FIBERMET MICRO-PERFORATED   x    
α=0,65 MINERAL WOOL WALL FIBERMET MICRO-PERFORATED x      


The sound absorption classification was obtained according to the regulation ISO 354:2003 - ISO 11654:1997.

 

 

 

ZULASSUNG CLASSIFICATION
 

The General Approval for Construction (Allgemeine Bauaufsichtliche Zulassung) certifies the usability and applicability of the object of approval pursuant to the Building Regulations issued by the Länder (German Federal States).

 

ZULASSUNG THICKNESSES
CLASS MATERIAL CATEGORY PRODUCT 30 35 40 50 60 80 100 120 140
ZULASSUNG PIR POLYURETHANE ROOF DELTA 5 x   x x x x x x  
ZULASSUNG PIR POLYURETHANE WALL ALFA 2 x x x x x x x x x

 

 

ISOLPACK SpA
C.so Vittorio Emanuele II, 99
10128 Turin
 

Vat N°: 07439930012
 

FR  | DE  | ES 

 

“This website does not use third-party or profiling cookies, but only technical cookies required for navigation.“
© 1999-2022, ISOLPACK SpA. All rights reserved.